In hydraulic fault diagnosis, pressure is related to load, flow rate to velocity, and temperature to energy losses and oil operating conditions. Measuring only one of these values does not definitively determine the source of the fault. When recorded together and at the same time of operation, they help to differentiate possible causes.
For example, high pressure and low flow rate can be related to pump inefficiency as well as flow restriction or diversion. Low pressure, however, does not always mean healthy operation; it can also be seen in a situation where the load cannot be carried. The interpretation should begin with what the system should be doing at that moment.
Technical checklist
| Observed pattern | A situation that can be investigated. | Additional verification |
|---|---|---|
| The speed is constant, but the flow rate decreases with the load. | Internal leakage or entry problem. | Temperature and inlet conditions |
| The pressure drops along the line. | Flow resistance | Simultaneous measurement at two points. |
| The oil is heating up rapidly. | Continuous energy loss | Flow path and duty cycle |
| There is pressure, but no movement. | Mechanical obstruction or incorrect flow path | Circuit and mechanical analysis |
First, create a comparable working case.
The vehicle, load, pump speed, oil type, and measurement points are recorded. If the same fault symptom changes at different temperatures, hot and cold records are kept separately. The operating limits of the model are verified with the relevant pump and system documentation.
Matching the measurement times is important. Calculating instantaneous energy loss by matching the initial pressure with the temperature at the end of the cycle can be misleading. In dynamic events, a common time axis is used; in stationary measurements, it is checked whether the conditions are truly stable.
The relationships in the table provide diagnostic guidance; they do not, by themselves, constitute a definitive conclusion regarding component failure. Multiple causes can produce the same symptom.
Make the losses visible in numerical terms.
The product of the pressure difference across a constraint and the flow rate passing through that point helps to evaluate hydraulic power loss. When the pressure difference is in bar and the flow rate is in liters per minute, the power in kW is approximately found by dividing the product by 600.
Hypothetically, if a section has a pressure loss of 15 bar and a flow rate of 60 liters/minute, approximately 1.5 kW of hydraulic power is lost in that section. This is not an exact measurement of the total heat load of the system; it is a calculated value for the section under consideration. Other losses, operating time, and heat transfer to the environment are evaluated separately.
Return to the same measurement after the intervention.
A reduction in the symptom after part replacement is helpful; however, a comparison with the previous measurement pattern is necessary to confirm the cause. If the oil is colder or the load is lower, the entire difference observed cannot be attributed to the repair.
Sensor range and measurement uncertainty should also be preserved in the report. Instead of presenting boundary differences as significant improvements, the change that the device can discern is considered. Thus, maintenance decisions are based on traceable data rather than interpretation.
Start the diagnosis from the system's expected function.
Before interpreting the measurement values, it is necessary to explain what the circuit should be doing at that moment. The same pressure or flow rate is not expected during the lifting, holding, and lowering phases. The control position, load, and cylinder movement are defined together. This prevents a normal phase transition from being mistakenly considered a fault. Knowing at which stage the complaint occurs also facilitates the selection of measurement points and comparison conditions.
The symptom described by the operator and the technical diagnosis should be recorded separately. The statement "slow start" is an observation; the statement "pump faulty" is a result that needs to be verified. The initial record should keep the observation as clear as possible. The onset time of the symptom, its relationship to temperature, and information about the last maintenance should be added. This approach allows for the evaluation of different possibilities without locking the investigation into a single part from the outset.
Show the measurement points on the circuit diagram.
It is essential to know from which part of the circuit the pressure, flow rate, and temperature values are being obtained. Using the pump outlet pressure and tank temperature can be useful for some general assessments; however, it may not explain the instantaneous loss of a specific component. Marking the points on the diagram clarifies the scope of the data. Reports prepared by different services can also be compared using the same definitions.
The test setup is also evaluated because the addition of a measuring device can affect the flow path. The flowmeter's pressure drop, the temperature sensor's contact type, and the pressure connection's position can all influence the results. Device selection should not be based solely on the measurement range. The measurement setup, established with the system in a safe condition, must be operated within the manufacturer's permitted conditions. Necessary protective elements should not be arbitrarily deactivated for testing purposes.
Consider the warm-up in conjunction with the duty cycle.
Oil temperature is a combined result of heat losses and heat dissipated into the environment. A short-term measurement may not fully represent the temperature behavior after a long period of operation. Daily cycle count, waiting time, and ambient conditions should be recorded. The same system may exhibit different temperatures under more intensive operation. This difference alone does not prove that the pump is faulty or the tank is insufficient.
For example, two vehicles might be lifting the same load, but one might be waiting for a long time between cycles while the other is operating continuously. Temperature comparisons should take this difference in usage into account. If an increase in pressure drop is observed in a particular section, the flow and duty cycle in that section are also examined. Thus, heating ceases to be merely a number seen on a thermometer and becomes related to the operating behavior of the circuit.
Narrow down possible causes using univariate trials.
Replacing multiple parts simultaneously may alleviate symptoms, but it may not clarify which cause is at play. A more instructive process involves sequentially checking the possibilities within a proper technical plan. Key inputs such as measurement validity, RPM, oil condition, and flow path are verified first. Then, inspections are conducted on specific components. This sequence reduces the risk of unnecessarily replacing sound parts.
For each test, the expected result and how it might change the diagnosis can be written down. For example, if the pump outlet flow rate is found to be satisfactory, the investigation may need to shift to the valve or line side. If the result is different from what was expected, the first step is to assess whether the test conditions were correctly established. A measurement supporting a hypothesis does not mean it rules out all other possibilities. The decision should be based on the consistency of the different findings together.
Make the technical report available for use in case of a future malfunction.
The final file should include the initial indication, measurement conditions, the cause found, the action taken, and the verification result. Codes of the replaced parts and the documentation versions used can also be included. This information prevents the next service team from having to start the investigation from scratch. Simply stating "repaired" is not sufficient to explain what the procedure changed or why the problem might recur.
Pressure, flow rate, and temperature data transmitted to the hydromass system are more meaningful when presented with a common time or cycle definition. After verification, it must be demonstrated that the system completes the required operation under permitted conditions. An improvement in one value does not justify ignoring other important limitations. The goal of diagnosis is not the correction of a single indicator, but a system with the cause of the malfunction understood and operating conditions verified.
Conditions left unchanged in the diagnostic file should also be noted. If the oil, load, or measurement location is not the same, the difference between two trials cannot be attributed to a single component. If more than one intervention was necessary, the limit should be explained in the report. When the result is not definitive, the probable cause and the confirmed cause should be written separately. This clarity prevents the next team from making the same incorrect assumption as the previous estimate, ensuring the investigation proceeds from a more accurate point.
Frequently Asked Questions
Is high temperature necessarily a pump failure?
No. Continuous throttling, improper duty cycles, or inadequate heat removal can also be contributing factors. The flow path should be examined.
Is it sufficient to see all three values on a single screen?
Screen synchronization is meaningless if the measurement points and time relationships are incorrect. It is essential to know where and how the data is collected.
Are the standard values the same for every vehicle?
No. Load, geometry, components, and oil conditions vary. Comparison should be made within the technical limits of the respective system.
In the diagnostic file to be submitted to Hidromas, present the pressure, flow rate, and temperature records with the same cycle description. This approach helps prevent unnecessary part replacements.
Technical resources
1. Hidromas Axial Piston Pump User Manual
2. NIST measurement uncertainty assessment
Hidromas products and technical support
Last Posts
- How are pressure, flow rate, and temperature interpreted together in hydraulic fault diagnosis?
- Why Sensor Accuracy and Calibration are Important in Hydraulic Pressure Measurement
- Tipper Body Creeping Down: Cylinder or Valve Leakage?
- How to Evaluate Flow Rate Loss Under Load in a Hydraulic Pump
- How do you measure sudden pressure peaks in a hydraulic system?