Flow Rate Loss Under Load in Hydraulic Pumps | Hydromas

How to Evaluate Flow Rate Loss Under Load in a Hydraulic Pump

How to Evaluate Flow Rate Loss Under Load in a Hydraulic Pump — Hidromas

A decrease in the flow rate of a hydraulic pump under load does not, by itself, indicate that the pump needs to be replaced. The result cannot be interpreted without knowing the pump speed, oil temperature, inlet conditions, and the point where the measurement was taken. A sound assessment involves comparing flow rate measurements taken under the same conditions with the manufacturer's data and identifying other loss paths in the system.

A slow tipper body lift does not directly prove a low pump flow rate. A portion of the flow may be returning to the tank via another route, or the volume the cylinder needs to fill may be different than expected. Diagnosis should proceed without equating the symptom with a single component name.

Technical checklist

Variable Why is it retained during measurement? Misleading interpretation
Pump speed Determines the theoretical flow rate. The drop in rotation speed can be mistaken for wear and tear.
Oil temperature It affects viscosity. Different tests can be considered equivalent.
Outlet pressure It affects leakage and loading conditions. The no-load result can be transferred under load.
Measurement point It shows the actual flow path. Valve loss can be attributed to the pump.

First, accurately calculate the theoretical flow rate.

For a fixed displacement pump, the theoretical flow rate is calculated by multiplying the displacement by the rotational speed. When the displacement is cm³/revolution and the rotational speed is rpm, the result is divided by 1,000 to obtain liters/minute. Using consistent units prevents calculation errors.

Hypothetically, if a 60 cm³/rpm pump rotates at 1,000 rpm, the theoretical flow rate is 60 liters/minute. Under the same conditions, if the measured flow rate is 54 liters/minute, the simple volumetric efficiency ratio is 90 percent. This value is not the performance or acceptable limit of any particular Hidromas model; it indicates the calculation method.

In variable displacement pumps, the controlled displacement and control behavior must also be known. Comparisons made based on theoretical maximum flow rates may cause a normal capacity setting to appear as a malfunction.

What changes as the pressure increases?

During testing, flow rate, speed, and temperature are recorded simultaneously when pressure increases. Flow restrictions at the inlet and oil condition are also reviewed when assessing the possibility of internal leakage. The pump's operating conditions should be matched with the relevant model manual.

The pressure drop and measurement capacity generated by the flowmeter are important. The load application process should be performed with appropriate test equipment, within the manufacturer's specifications, and by qualified personnel. Randomly shutting off the outlet line to evaluate flow is not a reliable or safe method.

For example, if the flow rate is maintained at the pump outlet but a drop is observed in the cylinder line, the valve, connections, and other flow paths should be investigated. The drop at the pump outlet is read along with the speed record. Even if the engine speed remains the same, the actual speed of the pump should not be assumed without knowing the transmission ratio.

Verify which product the displacement information belongs to.

The product code on the pump must match the catalog line used. Different displacements, rotation directions, or connection options may exist within the same family. Assigning a nominal flow rate based solely on the product's appearance is incorrect. Before beginning the technical evaluation, the model designation and any subsequent modifications should be checked. The current configuration of a revised pump may differ from the original delivery document; the service record should explain this difference.

The transmission ratio must be known when switching from engine speed to pump speed. The same engine speed displayed on the vehicle screen does not necessarily indicate the same pump speed across different PTO configurations. The actual pump speed measured or verified in the test report should be used. Without this information, it is impossible to determine how much of the flow rate reduction is due to speed variation. Comparing the result solely to the maximum flow rate listed in the catalog can incorrectly indicate a fault when operating conditions are normal.

Do not leave suction conditions independent of output measurement.

Adequate oil supply to the pump is a key input for performance evaluation. Constraints in the suction line, unsuitable viscosity, or air ingress can affect flow rate behavior. These possibilities cannot be ruled out solely by looking at the outlet pressure. The inlet conditions, line configuration, and oil level of the relevant model must be considered together. Testing outside the operating limits specified in the pump manual does not provide a reliable comparison.

Oil level monitoring is also related to the position of the vehicle and cylinder. The volume circulating in the system and passing into the cylinder can alter the apparent level in the tank. Therefore, level observation should be performed under the conditions defined by the manufacturer. Symptoms such as foam or noise may be noted; however, these alone do not constitute a definitive diagnosis of suction. Measurement and observation are considered as supporting data within the same operating condition.

Evaluate the effect of the flow meter on the test.

When a flowmeter is added to the circuit, it introduces additional resistance and volume to the flow path. The device's range, compatibility with the oil, and pressure limit must be appropriate. Low flow rates falling outside the device's reliable measurement range can lead to misleading results. The calibration information and installation direction of the device used should be included in the report. When comparing the test setup to the conditions the pump encounters in normal operation, these differences should be explained.

It is particularly important whether the measurement is taken at the pump outlet or after the valve. If the components in between divert a portion of the flow, the low flow rate in the cylinder line cannot be directly attributed to the pump. When comparing the two points, a safe and appropriate test method is selected. Randomly blinding the circuit or disabling the protection element is not an acceptable method for understanding the true capacity of the pump.

Compare the temperature-dependent variation at the same load.

As oil heats up, its viscosity changes; this change can alter the balance of factors such as internal leakage and line resistance. When comparing cold and hot measurements, pressure and speed should be kept as similar as possible. Otherwise, it will be impossible to determine how much of the flow rate difference is due to temperature. Instead of recording the start and end temperatures of the test, the temperature at the specific measurement point should be recorded. This ensures that the data matches the correct operating conditions.

Hypothetically, if the flow rate at the pump outlet remains constant while the vehicle's movement slows down, the investigation can be directed towards the valve, line, and cylinder volume. If the pump speed decreases while the outlet flow rate decreases, the transmission conditions should be examined. These examples alone are not diagnoses; they are distinctions that guide the measurement plan. The final decision must be supported by manufacturer limits and the actual structure of the circuit. Part replacement should not be used as the first option to cover data deficiencies.

Verify the outcome of the repair along with the capacity requirement.

Recording data under the same pressure, speed, and temperature conditions after the pump has been repaired or replaced strengthens the comparison. A faster tipper body lift alone does not necessarily indicate that all operating conditions are satisfactory. Power requirements, heating, and return line behavior must also be evaluated. Providing both before and after measurements in the same table in the Hidromas technical application allows for a clear view of the impact of the intervention.

If the existing pump is functioning but cannot meet the application's required flow rate, the issue is not a malfunction but rather capacity selection. In this case, the cycle time target, cylinder volume, and the system's allowable limits are re-evaluated. A larger pump alone is not presented as a solution. The selection should be made by verifying whether the valves, tanks, and lines, along with the PTO and drive capacity, can handle the new flow rate.

The flow rate record should include both the pump's identification and the actual operating conditions of the drive source. Results obtained at different speeds are not assumed to belong to the same performance curve. If the connection or measuring device has been changed, this information is preserved. When comparing post-repair measurements with the previous method, the equality of conditions is checked. This allows for a more accurate assessment of whether the observed improvement is due to the change in the part or the test conditions, and prevents the result from being interpreted overly broadly.

Frequently Asked Questions

Is the pump, which runs well when cold but slowly when warm, worn out?

It is one of the possibilities. Oil selection, valve leakage, and operating conditions can also give similar symptoms. Comparative measurements at the same temperature and pressure are necessary.

Is it possible to calculate the flow rate solely from the lifting time?

If the required volume and movement phases are known, an approximate assessment can be made. However, this method does not directly provide all the information from the flowmeter measurement.

Would a larger pump solve the slowdown problem?

Increasing capacity without addressing the root cause can increase heat, power, and line losses. The actual flow rate requirement of the system must be determined first.

For the technical evaluation of the Hidromas pump, prepare a table containing the pump code, actual speed, oil temperature, and flow rate versus pressure. This record facilitates the differentiation between capacity requirements and performance losses.

Technical resources

1. Hidromas Axial Piston Pump User Manual

2. BIPM International System of Units

Hidromas products and technical support