The ISO 4406 cleanliness code expresses the amount of solid particle contamination in hydraulic fluid. It does not, by itself, indicate the viscosity of the oil, its water content, or whether it is chemically usable. When reading an analysis report, the cleanliness result should be evaluated in conjunction with other oil properties and equipment requirements.

Particle control in tipper hydraulics helps maintain the operating conditions of the pump, valve, and cylinder. However, it is not accurate to assign the same target code to all systems. The target should be determined by the current requirements of the components used and the operating conditions of the system.

Technical checklist

Area of analysis The information he provided A matter that needs to be considered separately.
Particle code Level of solid pollution The source of the particle.
Viscosity Fluid resistance to flow Amount of solid particles
Water analysis Water status according to the method used. All chemical breakdowns
Trend record Change over time The sole cause of the failure.

The logic of the ternary code

In common automated particle counting reports, the code is associated with particle levels counted at thresholds of 4, 6, and 14 micrometers, depending on the calibration definition. These should not be read as three independent dimensional ranges. Larger particles are also included in the total count above the smaller threshold.

Each digit of the code represents a range of the relevant count. An increase in the number indicates the presence of more particles. Including the measurement method, sample information, and the number of raw particles (if applicable) alongside the code facilitates interpretation. Older two-digit codes should not be compared with the new three-digit code without explanation.

How to set a cleaning goal?

First, gather the requirements for the components in the circuit. Elements like pumps and valves may have different recommended cleanliness levels. The overall goal of the system should be defined in the engineering assessment to meet these requirements.

Filter selection, tank ventilation, filling method, and maintenance practices all affect achieving the desired outcome. Simply installing a finer filter will not solve all sources of contamination. Hidromas user manuals and relevant model documentation are the primary reference points for determining product specifications.

Read trends instead of a single result.

Consecutive samples taken from the same system are valuable in showing whether contamination is increasing. However, results may not be perfectly comparable if the sampling point or method has changed. Maintenance events such as oil addition and filter changes should be added to the analysis record.

Let's hypothetically assume the code improved after maintenance. This change could be related to the effect of filtration; the addition of new oil or different sample conditions could also have affected the result. To understand the reason, evaluate the maintenance timeline together with the analysis data.

Why particle count alone does not explain the source.

High particle levels may be due to external contaminant ingress, assembly debris, or part wear. Counting alone does not always differentiate between these sources. Additional laboratory testing methods may be used as needed.

Even if the oil appears clean, fine particles may be present. Conversely, sample conditions can also affect the optical counting result. The laboratory's method notes and sample preparation are therefore important. A decision to replace parts should not be made based solely on a single code on the report.

How to progress beyond the target result

First, the representativeness of the sample and the accuracy of the recording are checked. If the result is confirmed, the filling, filtration, tank ventilation, and recently opened connections are examined. A technical service evaluation is performed while maintaining the safe operating conditions of the circuit.

It is beneficial to take a control sample from the same point and using the same method after the corrective treatment. Maintaining this level of performance is as important as achieving the target. Consistently high results should not be managed solely by frequent filter changes, but rather by investigating the cause of the contamination entry or production.

What information should be included in the service application?

Product codes, circuit diagram, oil type, sample date, operating hours, and last maintenance procedures should all be shared. The laboratory report should include not only the cleaning code but also the method and description sections. This information supports the interpretation of the analysis results within the correct system context during the Hidromas technical evaluation.

Accurately interpret the magnitude of the code change.

ISO 4406 codes are not particle numbers, but classes representing counting ranges. Therefore, it is incorrect to interpret a one-digit change in the code as an increase or decrease in a single particle. Different raw counts can also be found within the same code. In trend assessment, detailed counting data provided by the laboratory can facilitate understanding changes occurring near the limit.

For example, two measurements that are close together may be on different sides of the class boundary. Even if the code changes, the actual difference may be small. Conversely, the number of particles within a class may increase while the code remains the same. This does not mean the cleaning code is useless; it shows that the code is a practical summary. When a maintenance decision is needed, the measurement and sample conditions behind the summary should also be examined.

Place the reference sample at the beginning of the maintenance program.

Creating an initial log for a newly commissioned or serviced system is useful. This log determines which condition subsequent results will be compared to. Since fresh oil doesn't automatically mean the system is clean, initial verification is also performed. Filling equipment, hose assembly, and the protection of open connections can all affect the result.

The initial log should include a description of the oil, the system's operating status, and the last actions taken. If the filter or oil is changed later, these events should be visible on the timeline. This allows for investigation to determine whether an improvement in a result is due to operating conditions, maintenance intervention, or sampling differences. The aim of the reference is not to impose a single number on all vehicles, but to consistently track the development of the same system.

Record any changes to the measurement method.

When the laboratory or counting method changes, the conditions for comparison with previous results should be reviewed. Sample preparation, the suitability of the measuring instrument, and the reporting format can all affect the interpretation. A higher value in the new report does not directly prove a system deterioration. First, the difference between the methods should be explained; if necessary, the transition should be evaluated with comparable samples.

If the laboratory report indicates the presence of air or other contaminants in the sample, this information should not be overlooked. Simply taking the code portion of a suspicious result and transferring it to the maintenance schedule constitutes an incomplete assessment. The warnings and method descriptions in the report are crucial in determining the usability of the result. The technical team should not make component replacement decisions based solely on numbers without evaluating the reliability of the data.

Connect the cleaning objective to business practices.

Once the target code is determined, a filling, storage, and maintenance system must be established to maintain this target. The suitability of the filter element alone is not sufficient; the container in which the oil is transferred to the system and how the connections are maintained during maintenance are also important. If a connection is not established between the desired cleanliness level and the daily work method, the target becomes merely a number in a report.

In systems that consistently produce high results, the correction plan should be based on a specific contamination entry path or cause of contamination generation. The subsequent sample should demonstrate the effect of the treatment under comparable conditions. Sharing this treatment history along with the analysis report in the Hidromas technical evaluation ensures that the finding is considered not only as a laboratory output but also within the maintenance record of the actual circuit.

The filing format of the cleaning report also affects trend tracking. If the vehicle, sample point, and date are all in the same record, subsequent results can be correctly sequenced. Changes are noted if different laboratories or methods are used. The code should not be presented as a standalone product warranty or cause of failure. The technical commentary should consider the count result in conjunction with the maintenance history and relevant component requirements.

Frequently Asked Questions

Can oil with a good cleaning code necessarily be used?

Such a decision cannot be made in isolation. Other factors such as viscosity, water content, oxidation, and manufacturer maintenance conditions must also be considered.

Does the new oil provide direct, targeted cleaning?

This should not be assumed. Contamination may occur during storage, transport, and filling. The suitability of the new oil and filling method for the equipment requirements must be checked.

Can a single target code be assigned to each hydraulic system?

No. Component sensitivity and operating conditions vary. The target should be determined through relevant product documentation and engineering assessment.