Measuring Energy Use per Tipping Cycle | Hidromas

Measuring Energy Use per Tipping Cycle

Measuring Energy Use per Tipping Cycle — Hidromas

The hydraulic energy of a tipping cycle is found by summing the power consumption over time during the cycle. Power, in turn, can be calculated from the measured pressure difference and flow rate. Simply multiplying the highest pressure by the cycle time may not accurately represent the actual energy requirement in a process where pressure and flow rate vary.

The measurement limit must be defined from the outset. The hydraulic energy at the pump outlet is not the same as the engine's fuel consumption or the energy drawn from the battery by the electric drive. Transmission, engine, pump, and auxiliary equipment losses create different measurement limits.

Technical checklist

Online section Data to be measured The distinction to be noted
Lifting Pressure difference, flow rate, and duration. Values may change throughout the stroke.
Wait Drive and flow status Consumption can continue even when there is no activity.
Lowering Flow and drive status Motion due to gravity is considered separately.
Auxiliary consumption Electrical or mechanical input It may not be included in the hydraulic output.

Separate power from energy.

Power is the rate of energy transfer at a given moment. Energy is the total of this transfer over time. Therefore, kW and kWh are not interchangeable; consistent use of units is fundamental to comparison.

When pressure difference is used in bar and flow rate in liters/minute, hydraulic power is approximately calculated in kW using the formula pressure difference × flow rate / 600. If this power is constant, the energy is the product of power and time in hours. In variable cycle, short time intervals are calculated separately and then added together.

Hypothetically, a flow rate of 60 liters/minute at a pressure difference of 180 bar corresponds to 18 kW of hydraulic power. If this lasts for 30 seconds, the hydraulic energy will be 0.15 kWh. These values do not represent the consumption of a single Hidromas product and do not represent the entire actual cycle.

Make the comparison based on the same job.

If the load, lifting geometry, and operating speed of the two cycles differ, the energy results do not directly constitute a product efficiency comparison. Oil temperature, pump speed, and measurement points should also be recorded. Measurement uncertainty is important in interpreting small differences.

For example, observing higher instantaneous power in a shorter cycle does not necessarily mean that the total energy is also high. Power may increase as the cycle time decreases. Conversely, the continued operation of the drive during a long waiting period can increase non-motion energy consumption.

Where to look for improvement?

First, the phase at which energy is consumed is determined. Issues such as unnecessary waiting, high line losses, or pump speeds exceeding the requirement are investigated through measurements. Changing pressure limits or speeding up the cycle cannot be implemented as a cost-saving method without a geometry and safety assessment.

The report should include the cycle definition, load, measurement limit, raw data, and calculation method. This allows subsequent changes to be re-measured under the same conditions. The statement "it consumes less" only makes sense through a comparison with clearly defined limits.

Define the measurement limit on the diagram.

It should be clear which inputs and outputs are taken into account in the energy analysis. A hydraulic measurement starting from the pump outlet does not include the mechanical input losses of the pump. A measurement from the input of the electric motor presents a different scope. When comparing the two results, the limits should be made the same or the difference should be explained. Showing the measurement points in the diagram makes it easier for the reader of the report to understand what the calculation covers.

If only the lifting phase is measured in one vehicle while the entire duty cycle is recorded in another, the totals do not represent the same energy work. The start and end events must be defined in advance. The moment the control is given, the moment the pump starts generating flow, and the start of the chassis movement can all be different. A suitable limit is selected for the measurement purpose and maintained in all comparisons. This keeps the impact of small time differences on the energy result under control.

Calculate the variable power log over time.

In a real cycle, pressure and flow rate may not remain constant. Power values at short intervals are combined with their respective durations to find the total energy. The time unit used in the calculation must be explicit. Failure to convert the duration recorded in seconds to hours will result in a large error in the kWh calculation. The units in the measurement file and the spreadsheet must be defined using the same logic.

If there are gaps or interruptions in the data, these intervals should not be silently accepted as zero consumption. How the missing portion is handled is explained in the report. If an estimate has been made, it is separated from the measured values. The time matching of the sensors is also important; multiplying the pressure and flow rate from different moments can produce power values that did not actually occur. Therefore, the time order of the raw records should be checked before energy calculation.

Make waiting consumption visible separately from movement consumption.

Even if the housing is not moving, the drive or auxiliary systems may still be operating. The circuit's activity during standby should be understood from the diagram and measurements. The path the pump is using to return the flow, the status of the control system, and the duration the drive remains active are all evaluated. Automatically considering the period without movement as zero energy may result in an underestimation of total duty cycle consumption.

Reducing waiting time can be an operational improvement; however, control functions and safe operation requirements must be preserved. The operating time required by the operator is separated from unnecessary drive time. It should also be examined whether operation becomes more difficult or whether delays occur in another phase while energy is reduced after the change. The lowest result obtained in a single cycle may not represent the normal state of operation.

Explain the differences in load and cycle life when comparing them.

When different materials are transported in the same vehicle, unloading time and center of load can change. This can affect the energy record. The comparison should specify the load mass, chassis geometry, and material behavior. It is possible that a cycle using less energy has performed less work. Results are evaluated separately in similar task groups when necessary; combining different tasks into a single average can reduce interpretive power.

For example, if the tipper body is completely emptied in one test while material remains in another, the completed work is not the same. Energy data should be recorded along with the task result. Failed or incomplete cycles should not be removed from the list without justification. Their number is part of operational performance. Sharing representative records, rather than just the best cycle, during the technical discussion with Hidromas allows for a more accurate understanding of actual usage needs.

Consider small differences along with measurement uncertainty.

If the energy difference between the two options is small, sensor accuracy, sampling, and variation between repetitions become important. The result of a single cycle may not be sufficient to make a definitive claim of superiority. A suitable number of comparable measurements and explained methodology are required. The report can show the variation in results alongside the average. This allows for an assessment of whether the improvement deviates from normal fluctuation.

If an energy saving rate is to be given, the starting conditions of the comparison must be clear. The difference between a new product and an old, faulty system does not carry the same meaning as the difference in efficiency between two healthy products. Changed components and operating settings should be listed. The results of the measurement should only be used for the scope examined; it should not be assumed that the same rate will occur in different tools and tasks.

Translate the results into actionable improvement points.

After determining which phase of the cycle consumes energy, factors such as line losses, duty cycle, and drive control can be prioritized. The expected impact and verification method are defined for each proposal. Speed or pressure changes outside of safe operating limits are not considered a cost-saving method. The measurement-based approach transforms the consumption claim into a numerical and comprehensive technical assessment.

The energy report should clearly indicate time periods with data loss. Calculating the missing portion as zero consumption may result in an underestimation. If a period is completed with an estimate, the method and scope should be explained. Job descriptions are synchronized before combining records from different instruments. This arrangement makes it clearer at what confidence level the measured cycle energy can be used when making operational decisions.

Frequently Asked Questions

Can hydraulic energy be directly converted into liters of fuel?

Reliable conversion is not possible without knowing the drive efficiencies and operating conditions. Fuel measurement is a separate measurement limit.

Does the highest pressure determine consumption?

It's not the only determining factor. Flow rate, duration, and other phases of the cycle are also necessary.

Is the measurement taken with an empty tipper body sufficient?

It defines the idle cycle. Representative load conditions should also be evaluated to show the energy requirements of the actual workload.

When conducting an energy assessment with Hidromas, share your cycle history and measurement limits. This approach helps to concretize the variables affecting consumption.

Technical resources

1. BIPM International System of Units

2. NIST measurement uncertainty assessment

Hidromas products and technical support

Contact us

We are here to answer your questions and for co-operation opportunities. Get in touch now and we will find the best solution for you!